DIGITAL BEDSIDE SPECIMEN IDENTIFICATION AND CLOSED-LOOP TRACKING TO PREVENT LABORATORY SAMPLE ERRORS: A SYSTEMATIC REVIEW

Authors

  • Abdulelah Mohammed Alharbi, Abdulmohsen Abdulrhman Bedaiwi, Naif Rashed Alanazi, Mona Atiyah Mohammed Alsaidalani, Afnan Hail Albalawi, Khadijah Eid Albalawi, Amal Ahmed Awad Aljawhari, Saleh Ali Alatawi Author

DOI:

https://doi.org/10.5281/zenodo.24540420

Keywords:

specimen identification; wrong blood in tube; barcode; positive patient identification; closed-loop tracking; pre-analytical errors; patient safety; Saudi Arabia

Abstract

Background: Specimen misidentification and mislabelling are among the most serious pre-analytical failures in laboratory medicine because they can lead to wrong diagnoses and ABO-incompatible transfusion. Digital bedside identification (barcode or electronic positive patient identification, ePPID) and closed-loop specimen tracking are widely promoted as countermeasures, yet the evidence has not been synthesised with a Saudi and regional focus.

Objective: To synthesise evidence on whether digital bedside specimen identification and closed-loop tracking reduce specimen identification and labelling errors, and to compare the Saudi/regional evidence base with international findings.

Methods: Systematic review reported according to PRISMA 2020. PubMed (15 queries) and Consensus were searched on 23 November 2026. Records were screened by title and abstract; eligibility was assessed at abstract level by one reviewer. No protocol was registered, no formal risk-of-bias tool was applied, and findings were synthesised narratively (SWiM) with design-based certainty ratings.

Results: From 167 records identified (151 screened), 25 studies were included (5 Saudi, 0 other GCC/MENA, 20 international). Large audits place mislabelled ABO samples at about 0.7% to 1.1% and wrong blood in tube (WBIT) at roughly 1 to 4 per 10,000 samples. Before–after and comparative studies of barcode/ePPID systems reported 41% to 90% lower error outcomes (for example, adjusted WBIT 1 in 14,606 with ePPID versus 1 in 3,046 with manual identification), but one multi-site audit found no association with barcoding and residual WBIT persisted where ePPID was bypassed or misused. Evidence on closed-loop tracking was sparse (one RFID pilot; one scan-with-hard-stop study showing an 88.4% reduction in wrong tissue in block). None of the Saudi studies evaluated digital bedside identification; they documented pre-analytical rejection rates of 0.063% to 9.3%, dominated by haemolysis and clotting.

Conclusions: International evidence consistently favours digital bedside identification with enforced hard stops, but it is largely observational and of low certainty, and Saudi evidence is limited to baseline error surveillance. Prospective, controlled evaluations in Saudi hospitals are needed.

Downloads