REDUCING ADVERSE EVENTS DURING MRI SEDATION THROUGH IMPROVED RADIOLOGY–ANESTHESIA COMMUNICATION
Keywords:
Adverse Events, MRI Sedation, Radiology, Anesthesia, Communication, Patient Safety, Interdisciplinary Collaboration, Sedation Management, Perioperative Care, Risk ReductionAbstract
In children undergoing magnetic resonance imaging (MRI) sedation, communication failures between radiology and anesthesiology contribute to multiple adverse events. Inconsistent models for such interaction further complicate efforts to mitigate risk in this vulnerable population. To better understand these challenges, a survey of communication practices between radiology and anesthesia during MRI sedation at a large, multispecialty academic medical center was conducted.
Sedation remains a common requirement for MRI studies in children, despite the effort to avoid it owing to associated risks. The requisite collaboration with anesthesia tends to be informal, with minimal technology involved and wide variation in team adherence to safety practices (Mitra et al., 2020). Numerous adverse events related to sedation still occur, including patient movement compromising scan quality, excessive monitoring, protracted study duration, and interruptions linked to patient or technician miscommunication. These concern the broader institution, as radiology and anesthesia often receive separate accreditation and the reported incidents reflect on quality of care and patient safety (Muyiwa Owojuyigbe et al., 2017). Communication links enabling effective collaboration are not yet well documented in imaging or anesthesia literature.